DC BLOX Birmingham Data Center Campus

DC BLOX · Birmingham, AL · United States

Facility record

Lifecycle
OperationalSource-reported lifecycle
Location precision
exact
Address as listed
433 6th Street South
Coordinates
33.5006652, -86.8208315
Serving utility, source-reported
Not established
Operational capacity, source-reported
5 MW
Planned capacity, source-reported
60 MW
Source record updated
2026-10-28

Source-reported capacity; not metered consumption. Review underlying documents and notes. Planned capacity may include future phases and is not added to operational capacity here. The source may use facility, grid-feed or IT capacity definitions; consult the linked documents.

Coordinate precision is a source label, not an independent parcel survey. A marker does not confirm utility territory or establish an effect on residential bills.

Reported lifecycle history

No dated operational history is established in this record. Publication, discovery and source-update dates are not opening dates.

Source notes

Operator spec page states verbatim: "Up to 5MW critical load; expandable up to 60MW" and "31,000 sq. ft. initially; expandable up to 200,000 sq. ft.", with a planned expansion building of 263,000 SF. A campus-level stat block on the same page reads "4 Data Centers (Operational & in Development)", "294,000 Square Feet", "49 Critical MW (Committed & Planned)" — the 60MW and 49MW figures are stated on the same page and are not reconciled by DC BLOX; both are recorded verbatim rather than normalized. Cooling: the source's cooling list says only "N+1 cooling", "Hot aisle containment" and "High efficiency Direct Expansion (DX)", and its high-density section adds "Water-cooled rear-door heat exchangers per cabinet"; as of October 2026, it does not state how the facility rejects heat or whether any cooling water is evaporated, so the cooling type is recorded as unknown. Site is the former Ingalls Ironworks building; DC BLOX states it is the first multi-tenant data center in Alabama to hold Uptime Institute Tier III Certification of Constructed Facility. Coordinates are the OSM building polygon centroid for the parcel, which OSM independently tags as a data centre named "DC Blox Data Center". As of September 2026, investment, jobs and subsidies were not stated in any source found and had not been checked at the Jefferson County / City of Birmingham tier, so their absence here is a gap in the research, not an audited negative.